A model-specific guide to dual-channel blue/red control, U₀ > 0.9 uniformity, and documented PPFD for vertical racks and grow tents

Direct answer

The RX-G80-U195 is designed for indoor cultivation projects that need both high light uniformity and a controllable blue/red recipe. Its model-specific specification documents a 1215 × 1088 × 100 mm fixture, AC230–277 V input, 700 W U195 full-power mode, 1,300 µmol/m²/s average PPFD at 0.2 m, 910 µmol/m²/s at 0.46 m, and 1,960 µmol/s PPF under the stated dark-room test conditions.

The system uses two channels: CH1 is documented for seedlings and vegetative growth, while CH2 adds red light for flowering. The U195 full-power mode combines the channels for flowering and fruiting-stage use. Koray’s product material reports U₀ > 90% and U₁ > 80%, with an 8-inch/0.2 m close-range reference and no central hot spot in the cited test. These values are test references; a production rack or tent still requires its own PPFD and canopy-temperature map.

Why adjustable spectrum matters in a controlled recipe

Indoor crops do not remain in one biological stage. Seedlings and vegetative plants may need a different light balance from flowering or fruiting plants. A dual-channel design lets the operator record separate treatments rather than changing the entire fixture.

The RX-G80-U195 product specification describes:

  • CH1: more blue light for seedlings and vegetative growth.
  • CH2: more red light for flowering.
  • U195 full power: combined output for flowering/fruiting-stage use.

The exact recipe should be established through crop trials. A channel label is not a crop protocol; operators must document intensity, photoperiod, mounting height, cultivar, temperature, humidity, CO₂, and nutrient conditions.

RX-G80-U195 adjustable blue and red spectrum growth-stage recipe

How uniformity and spectrum control work together

A tunable spectrum is only useful when the light is distributed consistently across the canopy. Koray’s product material describes U₀ > 90% and U₁ > 80% for the RX-G80-U195 reference, and presents the secondary-optics design as a way to reduce central hot spots at close range.

For a rack or tent, the correct commissioning question is whether each plant position receives the intended treatment. Measure the canopy at the final fixture height, map edge and center PPFD, and test channel settings separately. NASA’s overview of LED plant-lighting systems similarly emphasizes adaptable light output and precision control for controlled plant growth. NASA Spinoff: LED Systems Target Plant Growth

RX-G80-U195 U0 uniformity and PPFD map at 0.2 metres

RX-G80-U195 specification snapshot

Parameter Documented RX-G80-U195 value Procurement interpretation
Fixture dimensions 1215 × 1088 × 100 mm Check rack/tent clearance and suspension points
Input AC230–277 V in the referenced U195 specification Confirm site voltage and final driver data
CH1 power 580 W Documented seedling/vegetative channel
CH2 power 120 W Documented flowering channel
U195 full-power 700 W Documented flowering/fruiting configuration
CH1 average PPFD 1,040 µmol/m²/s at 0.2 m; 710 at 0.46 m Measure at the final canopy plane
CH2 average PPFD 260 µmol/m²/s at 0.2 m; 200 at 0.46 m Treat as a channel-specific reference
U195 average PPFD 1,300 µmol/m²/s at 0.2 m; 910 at 0.46 m Dark-room, no-reflection reference
U195 PPF 1,960 µmol/s Product-sheet reference
Uniformity U₀ > 90%; U₁ > 80% in product material Verify with an installed PPFD grid
Rated life 50,000 hours at Ta ≤25°C in the referenced specification Confirm current datasheet and warranty
Control Multi-light dimming; compatible with Horti Guru Controller is additional; confirm wiring
Documented markings CE, RoHS, ETL in the referenced U195 product material Confirm certificate scope for the exact model

The specification states ±10% tolerance for optical and electrical data and identifies PPFD as a dark-room, no-reflection reference. Keep these conditions with any published table.

RX-G80-U195 secondary optics and close-range uniform-lighting reference

What the documented U195 comparison shows

Koray’s U195 material reports that the newer high-uniformity configuration saves 15% energy versus the previous generation for a comparable average PPFD reference of 1,000 µmol/m²/s: approximately 540 W versus more than 640 W in the cited comparison. The product image and source material also present 700 W U195 PPFD comparisons against competitor samples. These are test-specific claims and should not be converted into a universal ROI promise.

Comparison point RX-G80-U195 reference What the buyer should verify
Full-power input 700 W Metered site input and dimming setting
U195 average PPFD 1,300 at 0.2 m; 910 at 0.46 m Final canopy height and fixture spacing
Uniformity U₀ > 90%; U₁ > 80% Installed map and measurement grid
Energy comparison 15% saving claim versus previous generation Exact comparison sample, PPFD target, and operating profile
Spectrum control CH1/CH2/U195 Channel recipe and control-system compatibility

How RX-G80-U195 fits different applications

Seedlings and vegetative growth

Use CH1 as the documented starting channel for seedling and vegetative treatments. The operator should establish the PPFD and photoperiod for the crop rather than running the channel at a fixed intensity by default.

Flowering and fruiting

The product materials describe CH2 as a flowering channel and U195 full power for flowering/fruiting. Use a written recipe that records the transition timing and channel intensity.

Indoor racks and grow tents

The 0.2 m and 0.46 m reference distances provide two useful starting points for compact indoor layouts. Final mounting depends on crop height, rack clearance, target PPFD, leaf temperature, ventilation, and the desired planting density.

RX-G80-U195 dual-channel adjustable-spectrum LED grow light above an indoor cultivation rack

How RX-G80-U195 differs from other G80 spectrum configurations

Configuration Documented positioning Selection question
G80-G24 Fixed low-green full spectrum Is a simple full-cycle recipe preferred?
G80-U40B Full-spectrum configuration documented for vegetative/mother-plant use Is the crop protocol based on the U40B spectrum?
RX-G80-U195 Dual-channel blue/red control with U195 full power Does the project require a vegetative-to-flowering recipe change?
RX-G80-F99 Adjustable configuration documented separately Does the buyer need the F99 spectrum and its own model data?

These spectrum configurations are not interchangeable. Do not transfer U195 PPFD, PPF, power, or uniformity values to G24, U40B, or F99.

A commissioning checklist for RX-G80-U195

  1. Confirm the exact RX-G80-U195 configuration, input, spectrum, and driver.
  2. Define CH1, CH2, and U195 recipes for each crop stage.
  3. Install at the planned height and check mechanical and electrical clearance.
  4. Map PPFD at the crop plane for each channel state.
  5. Record canopy temperature, HVAC behavior, humidity, and photoperiod.
  6. Test dimming and multi-light control through the planned controller.
  7. Run a stability period before scaling the recipe across all racks.
  8. Store the lighting recipe with cultivar, growth stage, and environmental set points.

Frequently asked questions

What is RX-G80-U195?

It is a G80 dual-channel adjustable-spectrum configuration with CH1, CH2, and U195 full-power modes for controlled indoor cultivation.

What is the U195 PPFD?

The referenced specification lists 1,300 µmol/m²/s at 0.2 m and 910 at 0.46 m for the 700 W U195 configuration. These are dark-room, no-reflection test references.

What do CH1 and CH2 control?

CH1 is documented for seedlings and vegetative growth, while CH2 adds red light for flowering. The final recipe should be determined through crop testing.

What does U₀ > 90% mean in this article?

It is the uniformity reference stated in Koray’s product material for the RX-G80-U195 configuration. The installed rack or tent still needs a measured PPFD map.

Can RX-G80-U195 run at 0.2 m?

The product specification includes a 0.2 m test reference and describes close-range use without a central hot spot. Validate crop temperature, PPFD, and spacing before adopting that height.

Is Horti Guru compatible with RX-G80-U195?

The product material documents compatibility with Horti Guru multi-light control. Confirm the additional controller, wiring, and dimming interface for the final installation.

What is the documented energy-saving comparison?

Koray’s material reports a 15% energy saving versus a previous generation at a comparable average PPFD reference. Actual savings depend on the comparison fixture and operating profile.

Which certifications are documented?

CE, RoHS, and ETL are listed in the referenced U195 product material. Confirm the current certificate scope for the exact model and destination market.

Application and procurement conclusion

Choose RX-G80-U195 when the indoor cultivation project needs a high-uniformity G80 fixture, dual-channel blue/red control, and a documented U195 full-power mode. The best procurement decision is based on a crop-specific commissioning plan: channel recipe, PPFD map, canopy temperature, photoperiod, power input, control integration, and maintenance access.

Provide Koray with rack or tent dimensions, crop and growth stage, target PPFD/DLI, photoperiod, site voltage, controller requirements, humidity conditions, and desired spectrum recipe. Request the current RX-G80-U195 datasheet, certificate file, driver information, and installation recommendation before purchase.

Sources and evidence notes

  • Koray Opto-electronic, “G80 U195 Adjustable Spectrum High Uniformity Grow Light Horticulture LED Module”, including RX-G80/U195 dimensions, channel data, PPFD, PPF, power, uniformity, and test conditions.
  • Koray Opto-electronic, “G80-U195 High Uniformity Adjustable Spectrum Grow Light” specification, used for the U₀/U₁, energy comparison, and application context.
  • Koray Opto-electronic, “G80 Folding LED Grow Light” product page, used for the G80 family positioning and control context.
  • NASA Spinoff, “LED Systems Target Plant Growth”: spinoff.nasa.gov.

Confirm current specifications, certificate scope, warranty, thermal requirements, and crop-specific lighting protocol before publication or procurement.