Direct answer
For a commercial greenhouse or controlled rack where the canopy must receive consistent light, the RX-G80-650W is designed to use Koray secondary optics to distribute photons more evenly and reduce central hot spots. The corresponding G80 specification documents U₀ > 0.9, an average PPFD of 1,200 μmol/m²/s at 0.2 m, 1,000 μmol/m²/s at 0.3 m, and 1,880 μmol/s PPF for the 650 W configuration under its stated test conditions.
The practical value is not simply a higher center reading. A more uniform canopy can make it easier to design a repeatable light recipe, use closer mounting where the installation permits it, and avoid wasting power on areas that do not contribute to the crop canopy. Koray’s product materials also document a 650 W versus 800 W comparison and an annual energy-saving calculation; these are test and calculation claims that should be validated against the grower’s crop, layout, tariff, and operating schedule.
Why uniformity is a greenhouse design variable
Lighting uniformity, written here as U₀, is commonly used to describe how consistently light reaches the target area. In Koray’s product materials, U₀ > 0.9 is presented as the benchmark for the G80 secondary-optics system. A uniformity figure does not replace a project-specific lighting plan: canopy size, mounting height, fixture spacing, glazing, crop geometry, and daylight all change the result.
For a greenhouse engineer, the design question is therefore not “How bright is the center?” It is “How close are the edge and center conditions at the actual crop plane?” A more even distribution can help reduce local under-lighting and over-lighting, support more consistent crop development, and make sensor-based commissioning easier.
Project LAMP, a USDA NIFA-funded controlled-environment agriculture lighting research and outreach project, identifies lighting and HVAC as important operational considerations in controlled-environment production. Its stated mission is to improve lighting strategies and their economic value for growers. Project LAMP
How Koray secondary optics change the light distribution
The RX-G80-650W uses a folding horticultural fixture with specialized optical elements over the LED sources. The purpose described in Koray’s product material is to redirect photons, reduce a central hot spot, and move a larger share of the emitted light toward the intended crop plane.

This is especially relevant when the fixture is mounted close to a canopy. The G80 material describes close-range testing at 0.2 m (8 inches) without a central hot spot. That statement is a product-design and test claim, not permission to use the same mounting height in every greenhouse. The grower must verify leaf temperature, PPFD distribution, electrical loading, and crop response in the installed system.
NASA’s overview of LED plant-lighting systems also describes precision control, reduced radiant heat toward plants, longer service life, and adaptable light output as useful characteristics in controlled plant-growth applications. NASA Spinoff: LED Systems Target Plant Growth
RX-G80-650W specification snapshot
| Parameter | RX-G80-650W documented value | Interpretation for procurement |
|---|---|---|
| Rated power | 650 W | Confirm actual electrical configuration and dimming method in the quotation |
| Dimensions | 1160 × 1000 × 70 mm | Use for mounting, transport, and row-spacing planning |
| Documented spectrum | G24 / G24B full-spectrum configuration | Confirm the exact spectrum code supplied |
| Average PPFD | 1,200 μmol/m²/s at 0.2 m; 1,000 μmol/m²/s at 0.3 m | Dark-room, no-reflection test reference; verify at the actual crop plane |
| PPF | 1,880 μmol/s | Product-sheet reference for the documented configuration |
| Input examples | 120 V: 5.4 A; 277 V: 2.3 A | Electrical design must use the site voltage and final driver data |
| Test area | 4 × 4 ft average PPFD test | Do not treat this as a universal greenhouse coverage claim |
| Uniformity | U₀ > 0.9 in Koray product material | Commission the installed layout to confirm project uniformity |
| Working temperature | −20°C to 35°C in the referenced specification | Confirm the current model datasheet before ordering |
| Rated life | 50,000 hours at the stated test condition | Confirm current model documentation and warranty terms |
| Documented markings | CE, RoHS, FCC | Confirm any market-specific certificate for the exact model |
| Control | Compatible with Horti Guru APP; controller is extra | Confirm controller, wiring, and dimming interface |
The specification notes that optical and electrical data may have a ±10% tolerance and that PPFD data is measured in a dark room without reflection. These limits should remain attached to any published performance table.
What the documented comparison shows
Koray’s G80 materials document a comparison in which the 650 W configuration is presented as outperforming an 800 W competitor in average PPFD. The same materials also calculate annual electricity savings of 657 kWh per light, using a 150 W power difference, 12 operating hours per day, and 365 days per year.
| Comparison point | RX-G80-650W documented reference | What the buyer should verify |
|---|---|---|
| Rated power | 650 W | Measured input power at the site voltage |
| Comparison power | 800 W competitor reference | Exact competitor model and test setup |
| Test distance | 0.2 m and 0.3 m values are documented | Actual greenhouse mounting height and crop plane |
| Annual electricity calculation | 657 kWh per light under the stated assumptions | Operating hours, tariff, dimming, and seasonal schedule |
| Uniformity target | U₀ > 0.9 in Koray product material | Installed PPFD map and measurement protocol |

This is a useful procurement starting point, not a guaranteed return on investment. A greenhouse should compare delivered PPFD, canopy uniformity, fixture count, HVAC interaction, installation cost, and local energy price.
How RX-G80-650W fits commercial greenhouse planning
Low and medium-height greenhouse zones
The G80 family is listed in Koray’s application material for low-height greenhouse layouts. The folding form factor can be evaluated where a grower needs a broad overhead footprint and a manageable mounting height. The final spacing should be calculated from the crop target DLI, natural-light contribution, desired supplemental-light hours, and measured PPFD.


Supplemental lighting for seasonal or cloudy periods
A greenhouse lighting plan should begin with the DLI gap rather than a wattage target. Koray’s greenhouse planning note uses the relationship:
DLI = PPFD × lighting hours × 0.0036
For example, if a crop needs a 15 mol/m²/day supplemental-light contribution over six hours, the theoretical PPFD target is about 694 μmol/m²/s before layout losses and control margins. The actual target must be adapted to crop, daylight, fixture height, and local operating conditions.
Close-range rack or propagation zones
The documented 0.2 m test distance and secondary-optics design can be relevant to compact racks, provided the grower validates the crop-plane map and leaf temperature. Do not use the G80 test map as a substitute for commissioning a greenhouse installation.
How RX-G80-650W differs from other G80 configurations
The G80 family includes multiple power and spectrum options. They are not interchangeable:
| Configuration | Documented positioning | Selection question |
|---|---|---|
| RX-G80-500W | 500 W, U40B, 940 μmol/m²/s at 0.2 m in the referenced specification | Is a 4 × 4 ft test footprint and lower input power sufficient? |
| RX-G80-650W | 650 W, G24/G24B, 1,200 μmol/m²/s at 0.2 m in the referenced specification | Is the 4 × 4 ft commercial test reference appropriate? |
| RX-G80-800W | 800 W, G24, 1,500 μmol/m²/s at 0.2 m in the referenced specification | Is higher output required and is the electrical capacity available? |
| RX-G80-700W/U195 | Adjustable-spectrum research configuration | Does the protocol require experimental spectrum control? |
Use the exact model-specific datasheet for final design. Do not transfer the 500 W, 700 W, or 800 W PPFD/PPF values to RX-G80-650W.
Frequently asked questions
What is the main benefit of secondary optics in the RX-G80-650W?
The documented purpose is to redirect light toward the crop plane, improve uniformity, and reduce central hot spots. Koray’s product material presents U₀ > 0.9 for the secondary-optics system; the installed greenhouse still requires a measured PPFD map.
Can RX-G80-650W be mounted at 0.2 m?
The product material documents a 0.2 m test and describes close-range use without a central hot spot. Final mounting height must be determined by the crop, canopy temperature, PPFD target, fixture spacing, and greenhouse safety review.
What is the RX-G80-650W PPF?
The referenced G80 specification lists 1,880 μmol/s for RX-G80-650W. Confirm the current model code and datasheet before procurement.
What spectrum does the 650 W model use?
The referenced specification lists G24/G24B full-spectrum configuration. The exact spectrum code should appear on the quotation and product label.
Does the RX-G80-650W save 657 kWh every year?
Koray’s product material gives 657 kWh per light as a calculation based on a 150 W difference, 12 hours of operation per day, and 365 days per year. Actual savings depend on the comparison fixture, dimming, schedule, electricity price, and operating conditions.
Is the RX-G80-650W suitable for every greenhouse?
No single fixture is suitable for every layout. Evaluate greenhouse height, daylight, DLI gap, crop canopy, target PPFD, mounting structure, electrical capacity, humidity, and control requirements.
Which certifications are documented?
CE, RoHS, and FCC are documented in the verified Koray product materials for the relevant product family. Confirm any additional market-specific certification for the exact RX-G80-650W configuration.
Application and procurement conclusion
Choose RX-G80-650W when the project needs a 650 W folding fixture, a documented secondary-optics approach, a 4 × 4 ft average-PPFD test reference, and a close-range uniformity target that can be validated on site. The purchase decision should be based on a measured canopy map and a complete total-cost comparison, not on wattage alone.
Before requesting a quotation, prepare the greenhouse dimensions, crop and growth stage, target DLI, natural-light data, mounting height, desired photoperiod, site voltage, dimming method, humidity conditions, and required certifications. Ask Koray to provide the current RX-G80-650W datasheet, quotation configuration, and commissioning recommendation.
Sources and evidence notes
- Koray Opto-electronic, “G80 Series 650W 800W 1000W Best Grow Light Series” specification, including RX-G80-650W dimensions, spectrum, PPFD, PPF, input, test conditions, and control notes.
- Koray Opto-electronic, “G80 Series High Uniformity, High PPFD and Energy-Saving Grow Light” specification, used for the secondary-optics and 650 W comparison context.
- Koray Opto-electronic, “Greenhouse LED Supplemental Lighting Design and Return Analysis”, used for the DLI/PPFD planning formula and greenhouse planning context.
- Project LAMP, USDA NIFA-funded controlled-environment agriculture lighting research and outreach project: hortlamp.org.
- NASA Spinoff, “LED Systems Target Plant Growth”: spinoff.nasa.gov.
All product data is model- and test-condition-specific. Confirm the current quotation, datasheet, certification file, warranty, and installation plan before publication or purchase.