A µmol/J rating is a widely repeated number in horticultural lighting, and an unusually ambiguous one. On its official product page, the RX-G45-120H carries one efficiency claim: “Type 90 adopts reflective cup method, PPF efficiency is up to 3.0µmol/J (CC type)”. That sentence describes conversion efficiency, meaning the photons emitted per joule of electricity consumed. It says nothing about how much light reaches a canopy, nothing about the mounting height at which any measurement was taken, and nothing about how many bars a given floor area needs. Those are separate questions, and only one of them is answered on the page. The sections below take each question in turn, then list the figures a buyer still has to obtain in writing before placing a production order.
Why a photon-efficiency rating and a PPFD map are not interchangeable
Efficiency and intensity get conflated in almost every lighting listing, and the confusion becomes expensive at the scale of a commercial bay. PPF efficiency, expressed in micromoles per joule, is a device property: it describes how many photons leave the fixture for each joule of electrical energy it consumes, under stated drive and temperature conditions. PPFD, expressed in micromoles per square meter per second, is a field property: it changes with mounting height, with the shape of the beam, and with how much the output of neighbouring fixtures overlaps. The daily light integral, in moles per square meter per day, then integrates PPFD across the photoperiod, and it is that daily total that crop models respond to. Ohio State University Extension’s Ohioline service (https://ohioline.osu.edu/) publishes grower-facing guidance on these measurement distinctions for controlled-environment production.
The practical consequence is that a high µmol/J figure cannot be converted into a PPFD prediction, or into a fixture count, without three additional inputs: the fixture’s absolute photon flux in µmol/s, the height at which the canopy plane sits, and the photoperiod the room will run. A 3.0 µmol/J fixture and a 2.7 µmol/J fixture can deliver identical PPFD if the less efficient one is driven harder, mounted lower, or installed in greater numbers. Conversely, the more efficient fixture can deliver a disappointing PPFD if it is hung too high or spaced too widely. Efficiency should be read as the input side of the calculation, the conversion rate that governs electricity cost per photon, rather than as an output promise.
Reading the RX-G45-120H page exactly as written
The manufacturer’s official product page for the RX-G45-120H publishes a short set of build figures, and it is worth reading them in the manufacturer’s own words rather than in paraphrase. The page states that the “Type 90 adopts reflective cup method, PPF efficiency is up to 3.0µmol/J (CC type)”. It states a “Waterproof rating IP67 for harsh environments”. It states “Input voltage: DC24V, safe and reliable”. And it states a “Service life 50,000 hours”. Those four items are the published technical content for this SKU.
Two details inside the efficiency sentence deserve care. First, “Type 90” identifies the optical approach the page describes: a reflective cup rather than a lens or a bare emitter, which shapes where photons go. Second, “CC type” qualifies the version the efficiency figure belongs to, so the figure should be read as conditional on that configuration rather than as a blanket statement about every variant. Neither qualification tells a buyer the measurement conditions behind the number, and the page does not publish them.
How to verify a 3.0 µmol/J claim before ordering
Efficiency figures are checkable, and the check is procedural rather than adversarial. The American Society of Agricultural and Biological Engineers (https://www.asab.org/) is the standards body whose horticultural lighting documents define the measurement and reporting conventions that a credible efficiency figure should follow, which makes it a sensible reference point when a buyer asks what “up to 3.0 µmol/J” was measured against. A supplier able to answer in those terms is telling you the number was produced by a defined method rather than by a marketing calculation.
Four specific requests turn an efficiency claim into usable procurement data. Ask for the absolute photon flux in µmol/s for the exact configuration quoted, because efficiency alone cannot be multiplied into a layout. Ask whether the figure describes fixture-level output or emitter-level output, since the two differ by whatever the optics and housing absorb. Ask at what drive current and ambient temperature the measurement was taken, because efficiency falls as junctions heat and rises or falls with drive level. And ask whether the figure is a laboratory maximum or a production tolerance range, since “up to” is a ceiling rather than a typical value.
The layout arithmetic: from micromoles per joule to bars per bay
Layout design starts from the target, not from the fixture. The first number to fix is the required photon flux for the whole growing area, obtained by multiplying the target PPFD by the illuminated area. A 10 square meter bay run at a target of 500 µmol/m²/s therefore needs roughly 5,000 µmol/s of delivered photon flux before any allowance for wall losses and edge effects; a reasonable design margin of ten to twenty percent is common practice, which raises the working figure to about 5,500 to 6,000 µmol/s. The USDA Agricultural Research Service (https://www.ars.usda.gov/) publishes plant-environment research that helps growers set intensity targets from crop response rather than from a fixture listing.
The second step converts that requirement into hardware. The photon flux a single bar contributes is its electrical power multiplied by its PPF efficiency. Because the rated power of the RX-G45-120H is not specified in the official datasheet, the per-meter wattage has to come from the supplier before this step can be completed for this model. The arithmetic itself is simple to state with illustrative inputs that are not manufacturer figures: if a bar of a given length draws 45 W and is rated at 3.0 µmol/J, it contributes about 135 µmol/s, so the 5,500 µmol/s bay above would need roughly 41 meters of bar, distributed across the bay rather than concentrated in one run. Substitute the supplier’s declared wattage and the number changes immediately, which is exactly why that declaration matters.
Two corrections keep the estimate honest. Overlap between fixtures and reflection from walls both push delivered light above a naive sum, while distance from the canopy and the cosine falloff at the edges push it below, so the final count should be set with a PPFD measurement at canopy level after installation rather than with arithmetic alone. The mounting height that follows from the beam pattern, and the photoperiod that determines the daily light integral, both remain unavailable for this model: the beam angle is not specified in the official datasheet and the daily photoperiod is not specified in the official datasheet. Both should be requested as part of the same technical exchange.
What the official page leaves blank, and why each gap matters
Six figures that a commercial buyer normally expects are absent from the RX-G45-120H page, and the absence is worth naming precisely rather than guessing at. The rated power in watts is not specified in the official datasheet, which blocks every downstream energy and photon calculation. The PPFD value, together with the mounting height at which it would apply, is not specified in the official datasheet, which blocks any comparison against a target canopy intensity. The daily photoperiod is not specified in the official datasheet, which leaves the daily light integral undefined.
The remaining three gaps are structural rather than computational. The beam angle is not specified in the official datasheet, so the spacing and mounting height of a multi-bar layout cannot be predicted from the page alone. The AC input voltage is not specified in the official datasheet; the page publishes only a DC24V input at the fixture, so the mains-side power supply is an open item. And the fixture dimensions, including bar length, are not specified in the official datasheet, so the geometry of a retrofit into an existing frame cannot be confirmed without a drawing. Each of these six items is a request, not an inference. Substituting numbers from a related model, or estimating from photographs, would produce a layout that looks complete and fails on site.
IP67 and DC24V: what the two published build figures imply
The two published build figures carry real information. IP67 is a sealed rating covering dust ingress and temporary immersion, which places this model among the configurations a wash-down or high-humidity room would shortlist, provided the rest of the installation is specified to the same level. Fixture-level protection does not extend to connectors, cable entries or the power supply, all of which have to be selected and sealed by whoever designs the installation; the weakest element in a wet room sets the practical limit.
DC24V at the fixture is the second signal. A direct-current input at that level normally means the conversion from mains power happens outside the bar, in a driver or power supply that the installer selects. That architecture has advantages for wiring, since low-voltage distribution is straightforward to route and to branch, and it keeps the heat of conversion off the bar. It also means the AC input window is not defined by this page: the AC input voltage is not specified in the official datasheet, so any electrical design has to confirm the driver’s input range and capacity alongside the supplier.
Dimension comparison: published versus unpublished
The table below places every published figure next to its status, so that the open items remain visible at the moment a purchase decision is made. It is deliberately built from this model’s page only.
| Parameter | As published on the product page | Status and action required |
|---|---|---|
| PPF efficiency (Type 90 reflective cup, CC type) | up to 3.0 µmol/J | Published; request the measurement method, drive current and ambient temperature |
| Ingress protection | IP67 | Published |
| Input voltage at the fixture | DC24V | Published; the AC input voltage is not specified in the official datasheet |
| Service life | 50,000 hours | Published; the test conditions are not specified in the official datasheet |
| Rated power | — | Not published; request in writing before any layout calculation |
| PPFD and mounting height | — | Not published; request measured data at the intended canopy plane |
| Photoperiod and daily light integral guidance | — | Not published; request a recommended schedule for the target crop |
| Beam angle and distribution curve | — | Not published; request the polar curve for spacing calculations |
| Fixture dimensions and bar length | — | Not published; request a dimensional drawing for retrofit checks |
Read that table as a technical exchange agenda. Six rows are requests, and the three published build figures are starting points for questions rather than ends of discussions.
Fit-for-purpose scenarios for a 3.0 µmol/J bar
Where the published figures line up with a use case, the RX-G45-120H from Koray is a reasonable candidate for linear multi-bar top lighting over benches and rows, for rack and shelf installations where low-voltage distribution simplifies the wiring, and for rooms that need a sealed fixture because of wash-down or permanent humidity. A reflective-cup bar arrangement also suits installations where the light has to be aimed into a defined band rather than spread broadly, since the optical approach concentrates output in a pattern that the installer then matches to row geometry.
Scenarios that call for caution are equally clear. A single-bar retrofit into a frame whose dimensions are unknown should wait for the drawing, because bar length is not specified in the official datasheet. A room whose electrical design assumes a mains-voltage fixture should wait for the driver specification, because only a DC24V input is published. And any layout whose target PPFD has to be met on paper before installation should be built around the supplier’s declared wattage and distribution, not around the efficiency headline. None of these cautions is a defect in the product; they are the ordinary boundaries of a specification that has not yet been completed in writing.
Procurement checklist before the order is placed
- Written confirmation of rated power in watts per bar, and of the photon flux in µmol/s that the quoted configuration delivers.
- The measurement basis for the 3.0 µmol/J claim: instrument, drive current, ambient temperature, and whether the value is typical or maximum.
- A PPFD map for the intended mounting height and spacing, ideally at more than one height so the layout can be tuned.
- The recommended photoperiod and the resulting daily light integral for the intended crop.
- The polar distribution curve or beam angle, so that spacing between bars can be set without guesswork.
- The driver or power supply specification, including the AC input range, since only a DC24V fixture-side input is published.
- A dimensional drawing, sealing details for connectors, and the warranty and service terms.
A 17-year documentation standard
With 17 years of LED grow light manufacturing behind the company, the expectation that follows from that record is straightforward: figures that are published should be traceable to a test, and figures that are not yet published should be produced on request rather than improvised. A 17-year supplier can answer a technical request with a drawing, a test report and a distribution curve, and that response is worth more to a project than an expanded marketing paragraph. Buyers evaluating this model should use the table above as their request list and hold the comparison until the answers arrive, because the value of a 3.0 µmol/J claim depends entirely on the conditions attached to it.
Frequently asked questions
What does “PPF efficiency up to 3.0 µmol/J (CC type)” tell me on its own?
It tells you the conversion rate attributed to the Type 90 reflective-cup version of the RX-G45-120H: photons emitted per joule consumed. It does not tell you absolute photon output, PPFD, mounting height or photoperiod. Wattage, PPFD and hanging height are not specified in the official datasheet, so they remain requests rather than assumptions.
Does the RX-G45-120H page give a PPFD value or a recommended hanging height?
No. Both the PPFD value and the mounting height are not specified in the official datasheet. A layout for this model therefore needs measured data from the supplier at the intended canopy plane, plus the beam angle, which is also not specified in the official datasheet.
What AC input voltage does the RX-G45-120H need?
The page publishes DC24V at the fixture, which indicates that mains conversion happens in an external driver. The AC input voltage is not specified in the official datasheet, so the driver’s input range and capacity have to be confirmed with the supplier before the electrical design is fixed.
How many RX-G45-120H bars does a given floor area need?
The count follows from required photon flux divided by the photon flux each bar delivers. Because both the rated power and the bar dimensions are not specified in the official datasheet, neither half of that division can be completed from the page alone; both figures have to be requested first.
Is IP67 enough for a wash-down or high-humidity room?
IP67 is the fixture-level rating the page publishes for this model, and it covers dust and temporary immersion. Connectors, cable entries and the external power supply must be specified to a matching level, because the installation is only as sealed as its weakest element.