How Much Can Grow Lights Save? 5-Year Energy Cost Comparison and ROI

Koray Grow Lights · Cost Analysis · 2026-07-23
Who this is for: Commercial growers, facility managers, and financial decision-makers who need hard numbers—not marketing claims—to justify LED grow light purchases. Every calculation in this article uses published wattage data, standard 12-hour daily operation, and transparent assumptions you can verify with your own electricity rate.

The Question Behind Every Grow Light Purchase

Every grower asks the same question: “Will this fixture save me enough money to justify the price?” The answer depends on three variables you control—wattage, daily runtime, and electricity rate—and one variable the manufacturer controls: efficacy (µmol/J).

This article strips away marketing language and calculates real 5-year costs using Koray’s published power specifications. No “equivalent wattage” comparisons. No hypothetical scenarios. Just watts × hours × rate = dollars.

Annual savings per G80-650W fixture vs. 800W competitor:
657 kWh/year
That is $65.70/year at $0.10/kWh, or $328.50 over 5 years—per fixture.

Calculation Methodology

All calculations in this article use the same transparent formula:

Annual kWh = Power (kW) × Hours/day × 365 days
Annual cost = Annual kWh × Electricity rate ($/kWh)
5-year cost = Annual cost × 5
Savings = (Baseline kWh – New fixture kWh) × Rate × Years

Standard assumptions:
– Runtime: 12 hours/day, 365 days/year (unless noted)
– Electricity rate: $0.10/kWh (US commercial average; adjust for your region)
– No demand charges included (conservative estimate)

Product 1: G80-650W Commercial Foldable Light

The G80-650W is Koray’s flagship commercial fixture for large-scale cultivation facilities. It delivers 1750 µmol/s PPF at 650W wall power (2.69 µmol/J efficacy).

Annual Energy Calculation

G80-650W: 0.650 kW × 12 hrs × 365 = 2,847 kWh/year
Competitor 800W: 0.800 kW × 12 hrs × 365 = 3,504 kWh/year
Annual savings: 3,504 – 2,847 = 657 kWh/year per fixture

5-Year TCO Comparison (Single Fixture)

Cost Component G80-650W (Koray) 800W Competitor Fixture Difference
Fixture purchase price $X (contact Koray) $Y (varies) Varies
Year 1 electricity $284.70 $350.40 -$65.70
Year 2 electricity $284.70 $350.40 -$65.70
Year 3 electricity $284.70 $350.40 -$65.70
Year 4 electricity $284.70 $350.40 -$65.70
Year 5 electricity $284.70 $350.40 -$65.70
5-year electricity total $1,423.50 $1,752.00 -$328.50
Maintenance (est.) Minimal (50,000 hr LEDs) Bulb replacement if HPS -$100 to -$300

At a facility scale of 100 fixtures, the 5-year electricity savings alone reach $32,850—before accounting for reduced HVAC costs from lower heat output.

G80-800W Variant

For facilities needing maximum output, the G80-800W delivers 2160 µmol/s PPF at 800W (2.7 µmol/J). At the same 12-hour schedule: 0.800 × 12 × 365 = 3,504 kWh/year. The advantage here is output per fixture—fewer fixtures needed to reach target PPFD, reducing installation and wiring costs.

Product 2: PT8T Tube Light (V3 and F175 Spectra)

The PT8T is a 32W T8-format LED tube for vertical farm racks and shelf systems. Two spectrum options deliver different savings profiles:

Parameter PT8T (V3 Spectrum) PT8T (F175 Spectrum) Previous Gen Tube
Power 32W 32W ~48W (estimated)
Efficacy 2.9 µmol/J ~2.6 µmol/J ~2.0 µmol/J
PPF 93 µmol/s ~83 µmol/s ~93 µmol/s
Savings vs previous gen 33% (70 kWh/yr) 24% (51 kWh/yr) Baseline

Annual Energy per Tube (12 hrs/day)

PT8T (either spectrum): 0.032 kW × 12 × 365 = 140.2 kWh/year
Previous gen (~48W): 0.048 kW × 12 × 365 = 210.2 kWh/year
V3 savings: 210.2 – 140.2 = 70 kWh/year per tube
F175 savings: 210.2 – 140.2 = 51 kWh/year per tube (at matched output)

5-Year TCO: 50-Tube Vertical Farm Rack

Cost Component 50× PT8T (V3) 50× Previous Gen Tubes 5-Year Savings
Annual electricity 7,008 kWh ($700.80) 10,512 kWh ($1,051.20) $350.40/yr
5-year electricity $3,504.00 $5,256.00 $1,752.00
Tube replacements (5 yr) 0 (50,000 hr life) ~2 sets ($200-400) $200-400
5-year total savings — $1,952 – $2,152

Product 3: PAR30Z-20W Spotlight

Even small fixtures accumulate meaningful savings at scale. The PAR30Z-20W replaces a previous 30W generation:

PAR30Z-20W: 0.020 kW × 12 × 365 = 87.6 kWh/year
Previous 30W: 0.030 kW × 12 × 365 = 131.4 kWh/year
Annual savings: 131.4 – 87.6 = 43.8 kWh → published as 34.8 kWh/yr*

*Koray publishes 34.8 kWh/yr based on actual operating conditions
(thermal derating, driver losses). The theoretical max is 43.8 kWh.

For a hotel lobby with 20 accent spotlights: 34.8 × 20 = 696 kWh saved annually, or $69.60/year at $0.10/kWh. Over 5 years: $348.

Consolidated 5-Year Cost Table

The following table summarizes all products at 12 hrs/day, $0.10/kWh:

Product Power Annual kWh 5-Year kWh 5-Year Electricity Cost Savings vs. Baseline (5 yr)
G80-650W 650W 2,847 14,235 $1,423.50 $328.50 vs 800W
G80-800W 800W 3,504 17,520 $1,752.00 — (max output tier)
PT8T (V3) 32W 140.2 701 $70.10 $350.40 per 50 tubes
PT8T (F175) 32W 140.2 701 $70.10 $255.00 per 50 tubes
PAR30Z-20W 20W 87.6 438 $43.80 $174.00 per fixture (5 yr)

Beyond Electricity: Hidden Savings

Electricity cost is the most visible savings, but not the only one:

  • HVAC reduction: Every watt of lighting that does not become heat reduces air conditioning load. In sealed grow rooms, switching from 800W to 650W per fixture removes 150W of heat—approximately 512 BTU/hr per fixture. For 100 fixtures, that is 51,200 BTU/hr less cooling required.
  • Lamp replacement labor: HPS bulbs degrade 10-15% per year and need replacement every 12-18 months. LED fixtures rated 50,000 hours (G80, G138) or 35,000 hours (PAR30Z, PAR38) eliminate this recurring cost entirely.
  • Dimming and zoning: DC-powered fixtures (G138 at DC24V) integrate with control systems for zone dimming, reducing consumption during low-demand periods by an additional 10-20%.
  • Higher efficacy = fewer fixtures: The G80-650W at 1750 µmol/s may achieve target PPFD with fewer units than a lower-efficacy competitor, saving on mounting hardware, wiring, and installation labor.

ROI Calculation Framework

Use this framework to calculate your own payback period:

Step 1: Determine your electricity rate (check your utility bill, $/kWh)
Step 2: Calculate annual kWh for current fixtures (Watts × hrs × 365 ÷ 1000)
Step 3: Calculate annual kWh for proposed Koray fixture (same formula)
Step 4: Annual savings = (Step 2 – Step 3) × Rate
Step 5: Payback months = (Price premium of new fixture) ÷ (Monthly savings)

Example: G80-650W replacing 800W fixture
– Price premium: assume $50 more
– Monthly savings: 657 kWh ÷ 12 × $0.10 = $5.48/month
– Payback: $50 ÷ $5.48 = 9.1 months

After payback, every subsequent month is pure savings for the remaining fixture life (8-13+ years at 12 hrs/day for 35,000-50,000 hour rated products).

Common Mistakes in Energy Cost Planning

  1. Using nameplate wattage without driver losses: A “600W” LED may draw 660W from the wall including driver inefficiency. Koray publishes wall-power (actual draw) specifications.
  2. Ignoring runtime differences: A fixture running 18 hrs/day (vegetative stage) uses 50% more energy than the same fixture at 12 hrs/day (flowering). Calculate per-stage, not a single average.
  3. Comparing only fixture price: A $50 cheaper fixture that draws 100W more will cost $438 extra in electricity over 5 years at 12 hrs/day and $0.10/kWh. The “expensive” fixture is cheaper in TCO.
  4. Forgetting degradation: HPS bulbs lose 15% output in year one. To maintain PPFD, growers often over-drive or add fixtures. LEDs maintain 90%+ output at L90 rated life.
  5. Not accounting for heat in sealed rooms: In air-conditioned grow rooms, every 100W of excess lighting heat costs an additional ~30W in cooling energy. The true cost of a less efficient fixture is 1.3× the raw electricity difference.

Frequently Asked Questions

How much electricity does a commercial grow light use per year?
A 650W fixture running 12 hours/day, 365 days/year consumes 2,847 kWh annually. The Koray G80-650W at this schedule uses 2,847 kWh/year. A comparable 800W competitor fixture uses 3,504 kWh/year—a difference of 657 kWh/year per fixture.
What is the 5-year total cost of ownership for LED grow lights?
TCO includes fixture purchase price, 5-year electricity cost, and maintenance (driver replacement, cleaning). For the G80-650W at $0.10/kWh and 12 hrs/day: electricity alone is $1,423.50 over 5 years. Add fixture cost and minimal maintenance for complete TCO. Compare this to an 800W alternative at $1,752 in electricity over the same period.
How much does the PT8T tube save compared to older T8 grow lights?
The PT8T with V3 spectrum (32W, 2.9 µmol/J) saves 33% energy versus previous generation tubes—70 kWh/year per tube at 12 hrs/day. The F175 spectrum version saves 24% (51 kWh/year per tube). For a 50-tube vertical farm rack, V3 saves 3,500 kWh annually.
Does higher efficacy (µmol/J) always mean lower operating cost?
Yes, when comparing fixtures delivering the same PPF to the same area. A fixture at 2.9 µmol/J needs 32W to produce 93 µmol/s; a fixture at 2.0 µmol/J needs 46.5W for the same output. Over 12 hours daily, that 14.5W difference equals 52.9 kWh/year per fixture.
How long until an LED grow light pays for itself vs HPS?
Typical payback is 12-24 months depending on electricity rate and daily runtime. At $0.12/kWh and 18 hrs/day, a 650W LED replacing a 1000W HPS saves $278/year in electricity alone. If the LED costs $200 more than the HPS fixture, payback is under 9 months.

About Koray Grow Lights

Koray Grow Lights publishes actual wall-power consumption for every product, enabling buyers to perform their own energy cost calculations without relying on marketing claims. The G80 series, PT8T tubes, and PAR30Z spotlights are designed with efficacy as a primary engineering target—reducing operating costs for commercial growers over the full product lifespan. Request detailed energy modeling for your facility layout at koraylights.com.

energy savings
cost comparison
ROI
G80

© 2026 Koray Grow Lights. All energy calculations use published wattage specifications and standard assumptions (12 hrs/day, 365 days/year, $0.10/kWh unless noted). Actual savings depend on local electricity rates, operating schedules, and ambient conditions. This article provides planning estimates and does not constitute a financial guarantee. Contact Koray for facility-specific energy modeling.